Logical Slot Failover
Spock creates logical replication slots on each provider node. For high availability with a physical standby, these slots must be synchronized to the standby so that replication can resume without data loss after a failover.
How It Works
When a primary server fails and a physical standby is promoted, any active logical subscribers must be able to continue replicating from the new primary. This requires the logical replication slots — which track each subscriber's replication position — to be present and up to date on the standby before the failover occurs.
Without slot synchronization, a failover would require manual slot recreation and a full re-sync of all subscriber tables.
Opt-in: spock.use_native_failover_slots
Starting with Spock 5, PostgreSQL's native slot-failover path (PG17+) is
opt-in, controlled by the boolean GUC spock.use_native_failover_slots
(default off). With the GUC off, Spock behaves exactly as before on
every PostgreSQL version: its own spock_failover_slots worker runs and no
slot carries the FAILOVER flag.
This GUC is PGC_POSTMASTER — it can only be set in postgresql.conf (or
ALTER SYSTEM) and requires a server restart to take effect; it cannot
be changed with SET or reloaded with SIGHUP.
The flag is read on the subscriber — the node that issues
CREATE_REPLICATION_SLOT against the provider to create its logical slot.
Set it there, not on the provider.
ZODAN's add_node path works differently: it checks the GUC via dblink
on the node that hosts the slot (the existing provider), not on the
node being added. Because this is a PGC_POSTMASTER GUC, set
spock.use_native_failover_slots uniformly on every node in the
cluster so both paths agree on the same behavior.
PostgreSQL Version Behaviour
| PostgreSQL | spock.use_native_failover_slots |
Slot sync mechanism | Spock worker |
|---|---|---|---|
| 15, 16 | off or on | Spock built-in spock_failover_slots worker |
Always runs on standby |
| 17 | off (default) | Spock built-in worker only | Always runs the full sync loop; no FAILOVER flag |
| 17 | on | Slots created with (FAILOVER); native sync_replication_slots (if enabled) |
Worker still registered but yields its sync loop when sync_replication_slots = on |
| 18+ | off (default) | Spock built-in spock_failover_slots worker |
Always runs; no FAILOVER flag |
| 18+ | on | Native sync_replication_slots (required) |
Not registered |
On PG15/16 there is no native slotsync mechanism, so the GUC has no effect; Spock's worker always handles synchronization regardless of the setting.
On PostgreSQL 17+, when the GUC is on, Spock marks every logical slot
with the FAILOVER flag at creation time. This enables PostgreSQL's built-in
slotsync worker to pick them up automatically.
On PostgreSQL 18+, when the GUC is on, Spock's own failover worker is
not registered at all. The native slotsync worker is the only mechanism. If
the GUC is left off (the default), Spock's worker is registered and runs
as it did before, and no slot carries the FAILOVER flag.
Setup: PostgreSQL 17 and 18+ (Native, requires spock.use_native_failover_slots = on)
On PostgreSQL 17 the Spock worker only steps aside once sync_replication_slots
= on is also set (step 4); on PostgreSQL 18+ with the GUC on, the Spock worker
is not registered and the native mechanism is required. The steps are the same
for both.
1. Enable the GUC on the subscriber
On the subscriber node (the node that creates the logical replication slot on the provider), set:
spock.use_native_failover_slots = on
This is PGC_POSTMASTER, so restart the subscriber's server after setting
it. Without this step, the slot is created without the FAILOVER flag and
none of the steps below take effect.
2. Create a physical replication slot on the primary
SELECT pg_create_physical_replication_slot('spock_standby_slot');
3. Configure the primary (postgresql.conf)
# Hold walsenders back until the standby has confirmed this LSN,
# preventing logical subscribers from getting ahead of the standby.
synchronized_standby_slots = 'spock_standby_slot'
4. Configure the standby (postgresql.conf)
sync_replication_slots = on
primary_conninfo = 'host=<primary_host> port=5432 dbname=<dbname> user=replicator'
primary_slot_name = 'spock_standby_slot'
hot_standby_feedback = on
5. Verify slot synchronization
On the standby, confirm that Spock's logical slots are synchronized:
SELECT slot_name, synced, failover, invalidation_reason
FROM pg_replication_slots
WHERE NOT temporary;
All Spock slots should show synced = true and failover = true.
6. After failover
After promoting the standby, subscribers only need to update their connection string to point to the new primary. Replication resumes from the last synchronized LSN with no data loss and no slot recreation required.
Important: if synchronized_standby_slots was configured (step 3 above),
you must adjust it on the promoted node before replication will resume — see
Runbook: clear synchronized_standby_slots after promotion
below.
Runbook: clear synchronized_standby_slots after promotion
When synchronized_standby_slots is configured (Setup step 3 above), the
provider's walsenders hold back logical decoding until every physical slot
named in that list has confirmed flush of the relevant LSN. This is what
keeps a physical standby from falling behind a logical subscriber — but it
has a sharp edge on failover.
When a standby is promoted, synchronized_standby_slots on the promoted
node still lists the physical slot(s) that fed replication to that node
before promotion. Those slots are now orphaned: nothing is consuming them
any more, so they never confirm, and the promoted node's walsenders sit
blocked waiting on them indefinitely. The practical symptom is that logical
replication to subscribers freezes immediately after a promotion that
otherwise looked successful.
The fix is a mandatory post-promotion step, not optional cleanup:
-- On the newly promoted node:
ALTER SYSTEM SET synchronized_standby_slots = '';
SELECT pg_reload_conf();
-- Then drop the orphaned physical slot(s) that fed the old topology:
SELECT pg_drop_replication_slot('spock_standby_slot');
If the new topology has its own physical standby(s), set
synchronized_standby_slots to the physical slot(s) for that standby
instead of clearing it to '' — the point is to remove references to
orphaned slots, not to leave the setting pointing at slots nothing will ever
consume.
Add this step to your failover runbook alongside the subscriber DSN update described above; skipping it is the most common cause of "failover succeeded but replication stopped" reports when native failover slots are in use.
Setup: PostgreSQL 15 and 16 (Spock Worker)
On PostgreSQL 15 and 16, the spock_failover_slots background worker runs
on the standby and periodically copies slot state from the primary.
Requirements
hot_standby_feedback = onon the standby (required for the worker to run)- The standby must be able to connect to the primary
Configuration GUCs
| GUC | Default | Description |
|---|---|---|
spock.synchronize_slot_names |
name_like:%% |
Slot name patterns to sync (all by default) |
spock.drop_extra_slots |
on |
Drop standby slots not matching the pattern |
spock.primary_dsn |
'' |
DSN to connect to primary (falls back to primary_conninfo) |
spock.pg_standby_slot_names |
'' |
Physical slots that must confirm LSN before logical replication advances |
spock.standby_slots_min_confirmed |
-1 |
How many slots from pg_standby_slot_names must confirm (-1 = all) |
spock.failover_slots_naptime |
1000 |
Worker sleep between slot-sync passes, in ms (SIGHUP; range 1000–3600000) |
spock.failover_slots_feedback_naptime |
10000 |
Shorter retry, in ms, while waiting for standby WAL feedback (SIGHUP; range 1000–3600000) |
Example (postgresql.conf on standby)
hot_standby_feedback = on
spock.synchronize_slot_names = 'name_like:%%'
spock.drop_extra_slots = on
# Optional: hold walsenders on primary until this standby confirms
# (set this on the PRIMARY, not the standby)
# spock.pg_standby_slot_names = 'physical_slot_name'
Monitoring
Check slot sync status (PG17+)
SELECT slot_name,
failover,
synced,
active,
invalidation_reason,
confirmed_flush_lsn
FROM pg_replication_slots
WHERE NOT temporary
ORDER BY slot_name;
Check if native slotsync worker is active (PG17+)
SELECT pid, wait_event_type, wait_event, state
FROM pg_stat_activity
WHERE backend_type = 'slot sync worker';
Check spock worker is running (PG15/16)
SELECT pid, application_name, state
FROM pg_stat_activity
WHERE application_name = 'spock_failover_slots worker';
FAQ
Q: Do I need to do anything after a failover?
On PG17+ with spock.use_native_failover_slots = on: update the
subscriber's host= in their DSN, and — if synchronized_standby_slots was
configured — clear/adjust it on the promoted node as described in the
runbook above.
No slot recreation is needed.
On PG15/16, or on PG17+ with the GUC left at its default off: Spock's
worker on the standby (now primary) stops running since it is no longer in
recovery. Subscribers reconnect automatically.
Q: What if sync_replication_slots is not configured on PG18 with the GUC on?
With spock.use_native_failover_slots = on, Spock's worker is not
registered on PG18+. If sync_replication_slots = on is not also set,
logical slots will not be synchronized to standbys, and a failover will
require manual slot recreation and table re-sync. (With the GUC left off,
this does not apply — Spock's worker is registered and runs as usual.)
Q: Can I use both mechanisms on PG17?
No, both can't run their sync loops at once, and this only matters if
spock.use_native_failover_slots is on in the first place. If it is on and
sync_replication_slots = on is also set on PG17, Spock's worker detects
this and skips its sync loop, deferring to the native worker entirely. With
the GUC off (the default), native sync_replication_slots has no effect on
Spock's slots since they are never marked with FAILOVER.
Q: Do I need to restart the server to enable this?
Yes. spock.use_native_failover_slots is PGC_POSTMASTER — it can only be
set at server start (via postgresql.conf or ALTER SYSTEM followed by a
restart), not with SET or a SIGHUP reload.